Execution Policy and Concurrent Playback
Whether reactions can overlap is set per blueprint in MARS Link. The policy summary shown in the Hub is read-only.
| Link setting | When set to Yes |
|---|---|
| Allow Re-running the Same Reaction | New requests for this reaction overlap even while it's already running |
| Allow Running with Other Reactions | This reaction can run alongside other reactions |
For two different reactions A and B to run simultaneously, both A and B must have "Allow Running with Other Reactions" set to Yes.
- For reactions that move the same target — such as motion or camera — start both at No.
- Set Yes only for reactions that are safe to overlap, such as throwing a single independent prop.
Extra Delay After Completion
Extra Delay After Completion in MARS Complete keeps the reaction marked "Running" for that many seconds even after signaling completion. Use it to add spacing before the next reaction starts.
If re-running the same reaction is allowed, a new instance of the same reaction can still start during this delay. This is different from a cooldown that blocks all calls.
Concurrent Runs and Link Data
When the same reaction runs in parallel, the data outputs of the Link node (Nickname, Message, Custom Parameter, etc.) point to the most recent call. Read data immediately after Invoked. Reading it after a Wait may give you the values from the next call. If you need to read data late, disable re-running.